Skip to main content

Table 2 Mutation calling performance (true-positive mutations and cross-patient negative calls)

From: DREAMS: deep read-level error model for sequencing data applied to low-frequency variant calling and circulating tumor DNA detection

 

Full alteration cataloga

Catalog alterations with signalb

 

Sensitivity

Specificity

Sensitivity

Specificity

F1

G-mean

DREAMS-vc

0.387

0.997

0.841

0.955

0.479

0.896

Shearwater

0.325

0.998

0.705

0.963

0.461

0.824

Mutect2

0.309

0.997

0.670

0.948

0.376

0.797

  1. aFull alteration catalog consisting of n = 191 true-positive mutations, and n = 12,900 potential cross-patient negative calls
  2. bCatalog of alterations with signal consisting of n = 88 true positive mutations, and n = 1330 potential cross-patient negative calls